LED Error Flash Codes
Hover over or click LED image to show flash pattern.
Bootloader ModeRapid flashes on startup for 500ms or continuous when in bootloader mode. | |||
Auto Addressing Error4x flash every 500ms of startup after a few seconds. Device will try to recover previously used address if available (if previously obtained an auto address and it is not the master address; 0x08). If this address is not available, the LED will flash indefinitely and device will not start. | |||
Bad Address Range (when setting address manually or there is greater than 112 devices)Continuous flash every 100ms. Device will not start. | |||
Sensor Initialisation FailureContinuous fade in. Device will not start. | |||
No Settings in EEPROM (program defaults loaded)4x 100ms flashes on startup. Device will continue to start. | |||
Factory ModeContinuous fade in and out. Continues to fade until factory mode exits. | |||
Calibration Failure4x 500ms flashes. Occurs after calibration if failure detected. | |||
Calibration Succeeded1x 200ms flash. Occurs after calibration if succeeded. |